Description
Instruments 4 Engineers are proud to be authorized UK distributors for 3ctest
The 3ctest CCS600 includes an intuitive 5.7 inch color touch screen for ease of use. The multifunctional compact immunity (EMS) test system is built with capability to meet all the requirements of international standards and product standards for EFT- Burst EN61000-4, transient pulse, surge EN61000-4-5 , PFMF EN-61000-4-8 with optional 3ctest MFT400/1200 and with the optional 3ctest VVT 2216SV voltage dip and variations EN61000-4-11. For more standards please see list below. The 3ctestCCS 600 is the best option for full compliance immunity test as per the requirements of EU CE certification,UKCA and CCC certification for single-phase devices.. It has an automatic single phase coupling/decoupling network built in and can be setup with a three phase coupling network for five wire testing up to 100 Amps.
Additional Standards:
> EN/IEC 61000-4-4
> EN/IEC 61000-4-5
> EN/IEC 61000-4-8
> EN/IEC 61000-4-9
> EN/IEC 61000-4-11
> EN/IEC 61000-4-29
> EN/IEC 61008-1
> EN/IEC 61009-1
> EN 61543
> GB/T 17626.5
> GB/T 17626.4
> GB/T 17626.8
> GB/T 17626.9
> GB/T 17626.11
> GB/T 17626.29
Specifications
General data
|
Display
|
5.7inch TFT color touch
screen
|
Power supply
|
AC 110V/220V,±10%,
50/60Hz,±5% (default AC 220V 50Hz)
|
Fuse
|
6A
|
Max power
consumption
|
200W
|
Memory space
|
Infinite(PC)
|
Communication
mode
|
Ethernet, RJ45
|
Dimension(W*H*D)
|
19inch/6U
|
Weight
|
Approx.41Kg
|
Temperature range
|
15-35℃
|
Humidity range
|
45%-75%
|
Air pressure
|
86kPa-106kPa
|
|
EFT/burst test as per IEC 61000-4-4
|
Test voltage
|
0.25kV-4.8KV(±10%)
|
Source impedance
|
50 ohm
|
Polarity
|
Positive, negative, alternative
|
Rise time
|
5ns±30%,50 ohm load,1000 ohm load
|
Pulse waveform
|
5/50ns,50 ohm and 1000 ohm load
|
Pulse frequency
|
0.1kHz-1000kHz
|
Pulse duration
|
50ns±30%,50 ohm load
|
Burst duration
|
0.075ms-750ms
|
50ns-15/+100ns,1000 ohm load
|
Test duration
|
1s-9999s
|
Burst cycle
|
11ms-9999ms
|
Synchronization
|
0° - 360°, 1° step or random
|
Trigger mode
|
Automatic, manual or external
|
CDN
|
Internal single phase automatic CDN: AC 220V 16A Max 250V
|
SURGE as per IEC61000-4-5
|
Test voltage
|
0.3kV-6kV (±10%)
|
Test current
|
0.15kA-3kA (±10%)
|
Voltage waveform
|
Front time: 1.2us±30%, Time to half value: 50us±20%
|
Source output impedance
|
2 ohm
|
Current waveform
|
Front time: 8us±20%, Time to half value:20us±20%
|
Coupling capacitance
|
9μF、18μF
|
Polarity
|
Positive, negative, alternative
|
Pulse cycle
|
5s-99s (shortest depends on test voltage)
|
Coupling resistance
|
10 ohm、0 ohm coupling resistor or customized
|
Number of test
|
1–999
|
Surge voltage and current peak detection
|
Front panel BNC output, surge voltage: 1000V:1V Surge current :500A:1V 3 digits on display
|
Synchronization
|
0° - 360°, 1° step or random
|
Trigger mode
|
Automatic, manual or external
|
CDN
|
Internal single phase automatic CDN: AC 220V 16A Max 250V
|
PFMF test as per IEC61000-4-8 with optional module MFT 400/1200
|
Magnetic field strength
|
TCXS 111 Single-turn coil: :1-100A/m (continuous)
100-400A/m (1-10s in short time)
TCXS 113 Single-turn coil :1-300A/m (continuous)
300-1200A/m (1-10s in short time)
|
THID
|
<5%
|
Current waveform
|
50Hz/60Hz sine wave
|
Operating current range for short time
|
120A-500A
|
Continuous operating current range
|
1A-120A
|
Test duration
|
1-28800s
|
Magnetic field output accuracy
|
Deviation less than setting output value 1dB(minimal magnetic field intensity like 1A/m needs to be adjusted manually before tests.)
|
Waveform interval
|
1-9999s
|
Coil size
|
1000*1000mm or others
|
Trigger mode
|
Auto ,manual, external
|
Coil turn
|
Single/three turn
|
Coil shape
|
Rectangle or others
|
Output magnetic field strength
|
Programmable setup
|
|
Pulse magnetic field test as per IEC 61000-4-9 with optional module PMC 1200
|
Output magnetic field range
|
100 A/m-1200A/m
|
Waveform
|
Rise time:6.4us±30%; duration: 16us±30%
|
Output current
|
100A-2000A
|
Polarity
|
Positive, negative, alternative
|
Synchronization
|
0°- 360°,1°step or random
|
Pulse cycle
|
5-99s(the shortest depends on test current)
|
Trigger mode
|
Auto ,manual, external
|
Coil shape
|
Rectangle
|
Number of test
|
1-999
|
Model of Coil
|
TCXS 111
|
Coil size
|
1000*1000mm
|
Output magnetic field strength
|
Programmable setup
|
Coil turn
|
Single
|
|
Power fail test as per IEC 61000 - 4 – 11 & IEC 61000-4-29 with optional module VVT 2216SV
|
EUT max. Voltage
|
250V AC,220V DC
|
EUT max. current
|
AC/DC 16A continuous current ; AC 20A continuous 5s;
40A continuous 3s;
500A impulse current
|
EUT current and voltage measurement
|
BNC terminal: voltage 100:1, current 10A:1V
|
Dip level
|
0%-100%(for VVT/VMT series)
0%,40%,70%,80%(for VVTxxxxSFseries)
|
Interruption level
|
0%
|
Dip and interruption interval
|
5ms-9999ms
|
Dip and interruption duration
|
0.1-9999 cycle or 1ms-9999ms
|
Dip and interruption rise/fall time
|
1-5µs (100Ωload)
|
Dip and interruption test duration
|
1s-9999s
|
Time of Voltage variation decreasing
|
500ms-9999ms(50%-100%) or 1-5us(100Ω load)
1000ms-9999ms(0%-100%) or 1-5us(100Ω load)
|
Voltage Variation level
|
0-100%
|
Duration after voltage variation decreasing
|
10ms-99999ms
|
Time of Voltage variation increasing
|
500ms-9999ms(50%-100%)
1000ms-9999ms(0%-100%)
|
Trigger mode
|
Auto ,manual, external
|
Synchronization
|
0°- 360°,1° step or random
|
|